Who needs to comply
Western Australia has two electrical safety rules that apply whenever a home changes hands or is let out. Around Busselton, with so many holiday homes and short-stay lets, they catch a lot of owners by surprise.
- Sellers, before the home is transferred at settlement
- Landlords of rental homes
- Holiday-let owners, including short-term rental accommodation
- Property managers acting for any of the above
WA smoke alarm rules
- Hard-wired to mains power. A 10-year non-removable battery alarm is allowed only where there's no hidden space to run the wiring and no suitable alternative spot, or with local government approval
- Working, and not past the expiry date on the alarm, or installed less than 10 years ago if it has none
- At least one in the hallway near the bedrooms on every level
- Interconnected where there's more than one alarm, unless the building permit was applied for before 1 May 2015
- Required before sale, rent or hire, including short-term rental accommodation
The full rules are on the WA Government's smoke alarm laws page.
Smoke alarm installation
An alarm that's past its expiry date, or installed more than 10 years ago if it has none, has to be replaced for a sale, rental or holiday let, even if it still beeps when you press the button. DFES advises replacing alarms every 10 years. Hard-wired alarms are connected to the home's wiring, so only a licensed electrician can install or replace them.
If an alarm is chirping rather than sounding, see why a smoke alarm beeps for what each pattern means and what you can fix yourself.
In older homes, it's worth asking about interconnected alarms even where they aren't required. When one alarm detects smoke, they all sound, which matters in a house where you might not hear an alarm at the other end.

WA RCD rules
- At least two RCDs protecting all power point and lighting circuits
- Sellers: in place before the title is transferred at settlement
- Landlords: installed in the switchboard of the rental home
- Short-term rentals: in place before guests stay
The details are on the WA Government's RCD safety switches page.
RCD testing
An RCD, or safety switch, cuts the power in a fraction of a second if current leaks to earth, such as through a faulty appliance or a person. WA's electrical safety regulator recommends testing each one every three months, or more often if the manufacturer says so:
- Find the RCDs on your switchboard. Each has a small button marked T or Test.
- Press the button once, without holding it down. The RCD should switch off.
- Switch it back on, then reset any clocks or timers on that circuit.
If an RCD doesn't trip, have a licensed electrician test it and replace it if needed. An electrician can also time how fast each RCD trips with calibrated equipment, which the button test can't show, and add RCDs to circuits that don't have one. If the board is old or full, that may mean a switchboard upgrade. If one keeps tripping on its own, see safety switch keeps tripping.
Before settlement or a new tenancy
Not sure where the home stands? The free smoke alarm and RCD checker for selling or renting in WA asks a few questions and gives you a printable checklist for the agent or property manager.
Book it early. Your settlement agent will want confirmation that both are in place, and electricians get busy before the summer holiday season. If the work needs an Electrical Safety Certificate, keep it with the sale or tenancy paperwork.
Buying rather than selling? A pre-purchase electrical inspection can check the switchboard, safety switches and wiring before your contract's inspection deadline.
Smoke alarm installation and replacement cost
No Busselton or South West electrician we checked publishes smoke alarm prices, so these are what Perth electricians and one cost guide publish. Most price the first alarm higher and each extra alarm in the same visit lower, so replacing every alarm at once usually costs less per alarm.
Published smoke alarm installation and replacement prices
| Job | Published price | Who publishes it |
|---|---|---|
| Replace an existing hard-wired alarm | $200 incl. GST, each additional $90 | Powerforce Electrical, Perth |
| Replace one hard-wired alarm, same position | $180 – $250 incl. GST | Web X Electricians, Perth |
| Each additional alarm, same visit | $120 – $180 incl. GST | Web X Electricians, Perth |
| 1 / 2 existing alarms replaced | $260 / $340 (GST not stated) | Westside Electrical, Perth |
| Single hard-wired alarm, supply and install | From $275 (GST not stated) | AVL Electrical, Perth |
| New mains-powered alarm, new position | $250 – $350 incl. GST | Web X Electricians, Perth |
| Three interconnected alarms | $600 – $900 incl. GST | Web X Electricians, Perth |
| Smoke alarm, supplied and installed, per alarm (low / typical / high) | $105 / $160 / $260 incl. GST | What's The Damage?, Perth |
Prices as published, checked 5 November 2026. Powerforce's undated list includes GST and a Clipsal photoelectric alarm, and adds $60 an alarm for a 10-year lithium type. Web X's (updated 16 September 2026) include GST, a photoelectric alarm with a 10-year backup battery and the safety certificate. Westside's and AVL's pages don't say whether GST is included; AVL's are starting prices. What's The Damage's Perth figures were verified November 2026. Busselton jobs can differ with travel and ceiling access.
By our arithmetic from Powerforce's list, replacing three existing hard-wired alarms is $200 + $90 + $90 = $380 including GST, or $560 with its 10-year lithium alarms ($60 extra each). Prices also depend on:
- whether each alarm replaces an existing hard-wired one or needs new wiring to a new position
- ceiling access, especially in two-storey homes or with raked ceilings
- whether the alarms need interconnecting (see the rules above)
- how many RCDs are needed, and whether the switchboard has room for them
For the WA rules in full, see smoke alarm and RCD rules in WA.
Common questions
How many smoke alarms do I need?
At least one in the hallway near the bedrooms on every level. Homes with bedrooms in separate wings, or more complicated layouts, often need more, so ask the electrician to confirm the number and positions when they quote.
How often should I test my RCDs?
WA's electrical safety regulator recommends pressing the test button on each RCD every three months, or more often if the manufacturer's instructions say so. If one doesn't trip, have a licensed electrician test it and replace it if needed.
Does a holiday let need compliant smoke alarms?
Yes. The WA smoke alarm rules apply to homes that are sold, rented or made available for hire, and that includes short-term rental accommodation.
Will I get an Electrical Safety Certificate?
For installing work, yes: the electrical contractor must give you one within 28 days of finishing. Maintenance work and like-for-like replacements don't need one, so ask your electrician whether your job does. See the Electrical Safety Certificate in WA.
Where these figures come from
The prices and rules on this page come from these published pages, checked on 5 November 2026.
- Powerforce Electrical: services and prices · Perth (south metro) electrician's published price list, incl. GST, undated
- Web X Electricians Perth: smoke alarm installation cost · Perth electrician's price guide, updated 16 September 2026
- Westside Electrical: smoke alarm install price · Perth electrician's fixed smoke alarm prices
- AVL Electrical: smoke alarms · Perth electrician's indicative smoke alarm prices
- What's The Damage?: electrician cost in Perth · Cost guide site, Perth prices verified November 2026
- Building and Energy: smoke alarm laws for homes being sold, rented and hired · WA regulator page (updated 26 November 2024)
- Building Regulations 2012 (WA), Part 8 Division 3 · WA legislation, smoke alarm regulations 55–62 (as at 23 July 2026)
- DFES: smoke alarms · WA fire service advice on smoke alarms
Related guides
- Pre-purchase electrical inspectionWhether you need one, how it differs from a building inspection, what it checks, common findings and published prices.
- Why is my smoke alarm beeping?What each chirp and beep usually means, what you can safely fix yourself, and when a hard-wired alarm needs an electrician.
- WA smoke alarm and RCD rules for sellers and landlordsThe deadlines for a sale, a lease or a holiday let, what counts as compliant, the penalties, and where an electrical safety certificate fits in.